The workflow and operating procedures of an ICP spectrometer!
发布时间: 2022-08-10 10:58
ICP emission spectrometer It is an inductively coupled plasma. Spectrometer ICP emission spectroscopy is an analytical technique that determines the concentration of an element by measuring the characteristic spectral lines emitted when excited atoms of the element return to their ground state. Thanks to its high sensitivity, high precision, and ability to analyze multiple elements simultaneously, ICP‑OES has been widely adopted across various analytical fields and has become a standard tool for inorganic elemental analysis in materials science, chemical engineering, and research. So, what is the workflow and operating procedure of an ICP spectrometer? Let’s briefly walk through it below.
I. Workflow of the ICP Spectrometer
1. The plasma supplies energy to vaporize the sample solution, forming gaseous atoms and exciting these atoms to emit light radiation.
2. The composite light emitted by the light source is dispersed by a monochromator into spectral lines arranged in order of wavelength, forming a spectrum; a detector is used to measure the wavelengths and intensities of these spectral lines.
3. Because atoms of the elements being measured have different energy-level structures, their emission lines also exhibit distinct characteristics. Accordingly, qualitative analysis of the sample can be performed, and quantitative determination of the elements can be achieved by correlating the concentration of the element under investigation with its emission intensity.
II. Operating Procedures for the ICP Spectrometer
1. Verify that the laboratory voltage is stable and that the temperature and humidity meet the experimental requirements.
2. Turn on the instrument’s power supply and allow it to stabilize for 30 minutes to ensure the instrument reaches its optimal operating condition.
3. Turn on the computer, launch the operating software, and verify the instrument’s stability.
4. Depending on the characteristics and physical state of the sample, select the appropriate sample preparation method. The tablet method is suitable for solid samples, while the liquid‑film method is suitable for liquid samples.
5. Place the prepared sample into the sample holder, insert the sample cell, and tighten the cap.
6. First, scan the background signal of the empty optical path, then scan the sample’s signal; the sample’s infrared spectrum is obtained via Fourier transform.
7. Print or save the infrared spectrum as needed.
8. When shutting down, first close the OMNIC software, then turn off the instrument’s power, followed by powering off the computer, and finally cover the instrument with its dust cover.
9. Record usage in the logbook.
10. The laboratory environment must maintain a stable temperature of 25±10℃ and a relative humidity of ≤70%.
11. The laboratory shall not perform any chemical treatment on samples; upon completion of the experiment, samples must be removed from the sample room immediately.
12. Sample preparation requires selecting an appropriate method based on the specific characteristics of the sample.
13. When the instrument is not in use, the petri dish should be filled with desiccant and placed in the sample chamber to keep the chamber dry.
14. The desiccant should be regularly inspected for moisture; if the blue color fades, it should be replaced promptly.
15. The desiccant can be reused after being baked in an oven at 105°C for approximately 3 hours.
16. When the instrument is not used for an extended period, it should be powered on periodically to maintain electrical connectivity and prevent moisture buildup.
17. After the experiment is completed, the instrument must be covered with a cloth cover.
18. The power supply used in the spectrometer laboratory must be equipped with a voltage regulator and a grounding wire.
The above is an overview of the ICP spectrometer’s workflow and operating procedures. If you require an ICP spectrometer, please contact Despu. Despu Instruments is a professional manufacturer of spectroscopic analytical instruments, offering instrument quotations and detailed information.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.