Causes of Heavy Metal Detector Malfunctions and How to Use It!
发布时间: 2022-08-03 10:17
As we all know, heavy metals are harmful to health and can significantly increase the risk of cancer. In large doses, they can even be fatal. Yet heavy metals are present in our daily environment—so how can we tell whether a particular item contains them? That’s where a heavy-metal detector comes in. This device can determine whether fruits, vegetables, meat, and soil around us contain heavy metals, and it can also measure their concentrations. Next, let’s take a closer look. Heavy metal detector Causes of occurrence and methods of use.

I. Causes of Heavy Metal Detector Malfunction
Food, soil, and water are increasingly contaminated by industrial emissions, wastewater, and solid waste. Some even irrigate crops directly with industrial wastewater, leading to the accumulation of high levels of heavy metals—such as cadmium, copper, arsenic, chromium, mercury, nickel, iron, aluminum, zinc, manganese, and others—particularly in suburban and urban areas. Coupled with the extensive use of synthetic chemical pesticides, heavy metal concentrations in vegetables and fish often exceed regulatory limits, accumulating in the human body and resulting in chronic heavy-metal poisoning across China. The country has experienced several mass‑poisoning incidents involving heavy metals, drawing serious attention from the government and widespread concern from all sectors of society. However, current methods for detecting heavy metals are slow, involve complex procedures, and are costly. In response, we have developed a rapid analytical method capable of simultaneously and swiftly determining lead, arsenic, chromium, cadmium, and mercury in food samples.
II. Instructions for Using the Heavy Metal Detector
1. Rinse the sample to be tested with distilled or purified water (to remove surface soil and avoid interfering with the analysis), allow it to air dry, then cut the sample into small pieces approximately 1 cm in size using a knife or scissors. Weigh out 1 g of the prepared sample, transfer it to a 20 mL plastic sampling tube, and add 10 mL of water.
2. Add 4 drops of Reagent A, use the stirring rod to press the sample below the liquid surface, cap the sampling tube, shake it up and down 10 times, let it stand for 1 minute, then shake it up and down another 10 times. Remove the fruit or vegetable sample; the resulting solution will serve as the sample to be analyzed.
3. Pipette 1 mL of the sample solution into the blank sample tube. Add 3 drops of Reagent B, cap the tube, and shake it up and down five times. Then add 2 drops of Reagent C and 2 drops of Reagent D, shake again five times, and allow the solution to develop color at room temperature for 5 minutes.
The above is an overview of the causes of malfunctions in heavy-metal detectors and their proper usage. If you have any questions, please feel free to contact us online or call for assistance. Heavy metal detector manufacturer -De Pu!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.