RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Common troubleshooting methods for thermal cracking equipment!
分类: News Center
发布时间: 2022-08-02 09:21
Pyrolysis equipment Solid waste is treated using anaerobic digestion technology. In typical applications, certain malfunctions may occur; below, we will… DPS RoHS environmental testing instrument manufacturer Let’s take a look at several common issues and their troubleshooting methods for thermal cracking equipment—interested readers, please stay tuned!
1. If the slag removal efficiency is low or slag discharge is blocked, check whether the pyrolysis furnace is rotating in the correct direction and whether the motor is malfunctioning.
2. Check whether the rotary seal is leaking; adjust the compression bolts or replace the graphite packing, and adjust the axial compensation of the bellows compensator. If the furnace door is leaking, replace the graphite packing.
3. If the rotary cracking furnace is not rotating, check whether the drive system’s motor, belts, and gears are operating normally, and verify that there is not an excessive amount of material inside the furnace.
4. System pressure has increased and is approaching 0.1 MPa; this may be due to a blockage in the piping. Immediately shut down the boiler, allow it to cool to 60°C, and reduce the pressure to 0 MPa (if a pressure gauge is present, open the pressure relief valve). Inspect, dismantle, clean, and clear the affected sections in stages.
The above outlines common troubleshooting methods for thermal cracking equipment. As we all know, using pyrolysis technology to process waste rubber and scrap tires is both simple and safe. The entire production process operates under slight negative pressure. Waste rubber and plastics do not require prior removal of impurities such as dirt, sand, moisture, or metal wires; they can be fed directly into the high‑temperature reactor. In a atmospheric‑pressure cracking unit, catalytic heating generates oil vapor, which then passes through a condenser: the condensable fraction is liquefied into a mixed oil, while the non‑condensable portion is combusted in the gas‑processing system. The condensed mixed oil is subsequently sent to a fractional distillation unit, where it undergoes catalytic reforming to produce distilled oil vapors. These vapors are further condensed in a condenser to yield base fuel oil, which is then subjected to sedimentation, filtration, and other chemical treatments, followed by the addition of various additives to produce qualified fuel.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.