Precautions for Using ROHS 2.0 Atomic Fluorescence Instruments!
发布时间: 2022-07-28 10:26
Many people are using it. RoHS 2.0 instrument Many people overlook numerous important considerations, which can shorten the lifespan of ROHS 2.0 instruments. So, what should you keep in mind when using a ROHS 2.0 instrument? Below, we’ll take the ROHS 2.0 atomic fluorescence spectrometer as an example to explain the proper procedures.
1. When replacing the element lamp, be sure to turn off the host power supply.
2. When powering on, follow this sequence: turn on the computer and wait for the Windows desktop to appear, then switch on the instrument’s main unit, and finally launch the software.
3. During instrument operation, it is best to avoid performing other computer tasks, especially those that consume substantial memory.
4. Instrument warm-up can be performed using the TEST method. The pump module can be clamped without pressure, and the instrument can run idly without any solution.
5. During measurement, monitor whether the waste‑liquid pump block is securely clamped and ensure that the waste liquid drains smoothly.
6. Do not allow the pump clamp to remain compressed against the pump tubing for extended periods. After use, promptly release the pump clamp. The pump tubing should be cleaned regularly and lubricated with silicone oil.
7. The reducing agent should be used and prepared immediately, and the standard series and standard stock solution should be replaced regularly.
8. Do not inject high-concentration samples, as this may contaminate the injection system. The maximum concentration of arsenic should be less than 200 µg/L (ppb), and that of mercury should be less than 20 µg/L (ppb).
9. The nebulizer should be disassembled and cleaned. If a vigorous reaction occurs or if liquid or bubbles have entered the nebulizer after one year of use, the quartz burner inside should be removed and cleaned by soaking it in a 10% nitric acid solution for approximately one hour, followed by air-drying or oven-drying.
10. After the waste‑liquid pump tubing is crushed, it can be reoriented to extend its service life. If both ends of the tubing are damaged, replace it with a new one.
11. After completing measurements, be sure to flush the sampling system with distilled or deionized water at least five times. If the instrument will remain idle for an extended period, it should be powered on at least once every two weeks—particularly in humid environments—to help maintain and prolong its service life.
12. Instruments operating under unstable local mains voltage should be equipped with a precision regulated power supply or a UPS rated at approximately 1000 watts.
13. All glassware used in the instrument must be dedicated and free from contamination, and the reagents employed must meet the required purity standards. In general, elevated blank values are primarily attributable to contamination of glassware or insufficient reagent purity.
14. The laboratory temperature should be maintained between 15 and 30°C. The laboratory must be kept clean and free from contamination; otherwise, measurements—particularly those of mercury—may be affected.
15. During use, check whether there is water in the water seal; if not, add water using a wash bottle.
The above is an overview of the precautions for using ROHS 2.0 atomic fluorescence instruments. If you have… RoHS 2.0 detector If you have any needs, feel free to contact or consult us online!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.