News Center

News Center

The working principle and characteristics of a pyrolysis analyzer!

发布时间: 2022-07-28 09:51

A thermal pyrolysis analyzer is an analytical instrument capable of detecting elements such as those specified in RoHS 2.0. Recently, many people have asked about its operating principle and key features. Below, we’ll provide a brief overview of how this instrument works and its distinguishing characteristics.

I. The working principle of the thermal pyrolysis analyzer!

Because the composition and relative abundances of pyrolysis fragments are closely linked to the structure of the polymer being analyzed, each polymer exhibits a unique pyrolysis chromatogram—what we refer to as its pyrolytic fingerprint. The reliability of such fingerprints is crucial for reproducible analysis. Even minor variations in pyrolysis temperature can significantly alter the product profile, rendering the resulting chromatograms incomparable. However, compared with other pyrolysis techniques, the Curie‑point pyrolyzer, owing to the specific nature of its sample‑loading method, ensures precise control of pyrolysis temperatures, facilitating accurate characterization of fragment compositions. Consequently, it has become an industry‑standard instrument for both qualitative and quantitative analysis. Thermal foil pyrolysis is suitable for handling both solid and liquid samples: for particulate or loose‑powder solids, simply wrap the sample in aluminum foil; for liquids containing non‑volatile solutes, apply a drop of solvent, allow it to evaporate, and then encase the residue in foil; and for volatile components, use specially prepared glass wool to absorb them before wrapping.

That concludes our explanation of the operating principle of the pyrolysis analyzer. Now, let us delve further into the characteristics of pyrolysis.

II. Main Performance Characteristics of the Pyrolysis Analyzer!

1. Touchscreen display for parameter input; features power‑off protection, can store 12 sets of settings, and allows on‑demand recall by file name.

2. The pyrolysis probe is constructed either as a platinum wire or a platinum ribbon. The platinum‑wire type is molded using quartz glass tubing as the filler, while the platinum‑ribbon type is molded with paint.

3. The instrument is equipped with a probe‑cleaning function, which performs high‑temperature cleaning of the probe or the sample quartz tube to remove residual substances.

4. The pyrolysis cell can be mounted on the chromatographic injector via a dedicated bracket.

5. The probe can be programmed to perform a 10-step pyrolysis heating sequence.

6. The instrument is equipped with a startup cable, enabling real-time connection and coordinated operation with gas chromatographs and mass spectrometers both domestically and internationally.

7. The instrument is equipped with an independent gas‑supply system, enabling convenient connection to a wide range of domestic and international gas chromatographs and mass spectrometers without requiring any modifications to the external gas lines.

8. Equipped with a synchronized start interface for the gas chromatograph and the chromatography workstation, enabling one‑click operation for sample preparation, injection, and analysis.

That concludes our presentation. We hope it has been helpful to you.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >