Steps for using a metal elemental analyzer!
发布时间: 2022-07-27 11:08
A metal element analyzer is a multi-channel photoelectric colorimetric analyzer used for multi-element analysis. It allows users to freely input or delete standard sample points and various coefficients, perform regression analysis iteratively, and select the appropriate calibration curve based on the correlation coefficient. So how should we use it? Let’s now go over the steps for operating a metal element analyzer!
During routine testing, each channel can directly read the percentage content without any conversion; simply press the print button to output the test results. Each channel can store multiple distinct calibration curves, eliminating the need for frequent recalibration, and each curve can be easily recalled and viewed, significantly broadening the instrument’s range of applications. The instrument operates on the principle that, under the action of a composite catalyst, the sample undergoes oxidative combustion at high temperature, producing nitrogen, nitrogen oxides, carbon dioxide, sulfur dioxide, and water. These gases are then carried by a carrier gas into the separation‑detection unit. After the adsorption column has captured and retained non‑nitrogen compounds, the nitrogen oxides are reduced to nitrogen, which is subsequently detected. The oxides of other elements are further separated and quantified—following the sequence C, H, S—through adsorption and desorption on an additional adsorption–desorption column. To ensure the proper operation of the metal element analyzer, it is essential to familiarize yourself with its operating procedures beforehand. Let us now discuss these in detail:

1. Open the argon and oxygen pressure regulators, and adjust the gas pressure to 0.2–0.4 MPa.
2. Turn on the instrument and the computer in sequence, double-click the workstation icon on the computer monitor to initiate the online connection between the instrument and the workstation, then enter your username and password and confirm; the workstation will then enter the initialization state.
3. After the workstation completes initialization, the main interface will automatically appear. Click the “LOADMETHOD” option on the workstation, select the appropriate method, and then click “OK” to confirm. The instrument will automatically download the method, after which you should wait until all system statuses display “OK,” at which point the instrument will enter the testing state.
4. Click the “START MEASUREMENT” button on the instrument; a sample information dialog box will automatically appear. After entering the sample information, press the “Start” key to proceed to the measurement interface.
5. Click the “STARTF2” button on the measurement interface; an autosampler prompt will automatically appear. Use a syringe to draw an appropriate sample volume and inject it into the instrument, then click “OK” to start the analysis and testing process.
6. After the analysis is complete, the measurement results screen will appear. Record the analysis results, then click the “Exit” icon on the workstation to return to the main workstation interface.
7. Click the “Exit” option on the workstation, then exit the software and shut down the computer.
The above is an overview of the procedures for using a metal elemental analyzer, provided for reference only. For more information on metal elements, please continue browsing other pages. For inquiries about this product, please contact us by phone or online consultation.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.