How to Use an Elemental Analyzer!

发布时间: 2022-07-26 10:50

About Elemental analyzer Many people are familiar with this instrument, but using it effectively requires a few key techniques. Today, we’ll walk you through how to operate an elemental analyzer—interested readers can learn more!

I. Instrument Connection and Power-On


Connect the host’s power outlet to the mains power supply using the power cord, and ensure the instrument is properly grounded (otherwise it may be susceptible to interference, leading to data fluctuations). Verify that the drain hose is securely installed (do not immerse the outlet of the drain hose in waste liquid, as this may cause drainage difficulties). Pour distilled water (the reference solution) into the colorimetric cuvette, then turn on the power switch. The instrument will display the unit name and the date, accompanied by an audible signal. Press the “Cursor” key to move the cursor and enter the year, month, and day, then press the “Confirm” key to complete the entry. If no changes are needed, you can directly press the “Confirm” key to proceed to the sample‑testing interface.

II. Zero-Input and Full-Scale Adjustments


During routine instrument operation, it is necessary to adjust the zero point and the full-scale range. The zero point generally does not require frequent adjustment; each time the instrument is powered on, simply press the “Zero” key to enter the sample‑testing interface. To adjust the full-scale range, on the sample‑testing interface, turn the full‑scale adjustment knob at the cursor’s position until the signal percentage reads approximately 100.0, then press the “Full Scale” key. The full scale will be calibrated to 100.0 ± 0.1. Follow the same procedure to adjust the full scale for other channels. Alternatively, full‑scale adjustment can also be performed in the standard‑sample calibration interface. In the standard‑sample calibration interface, when the cursor is positioned on the line displaying “T,” pressing the “Full Scale” key will calibrate the full scale to 100.0 ± 0.1.

III. Sample Testing and Printing

1. On the sample test interface, the cursor defaults to the *channel position.
2. First add the reference solution, then adjust the zero point and full-scale range.
3. Press the “Cursor” key to cycle the cursor through each channel.
4. Press the numeric keys (0–9) to call up the corresponding curve (items 0–9).
5. Drain the reference solution and add the color-developing solution for the sample. The value displayed in “C” represents the percentage content of the sample, the value in “T” indicates the transmittance, and the value in “A” shown in the middle is the absorbance.
6. Press the “Print” key followed by the number (1–4) to confirm printing the relevant parameters for the corresponding channel. Press “Print,” then “0,” and confirm to print the parameters for all four channels simultaneously.
7. Perform the remaining channel‑related measurements according to the steps outlined above.
8. Click the “Query” button to enter the query and modification interface.
9. Press the “Standard/Test” button to enter the standard sample calibration interface.

The above instructions for using the elemental analyzer are for reference only; this method is applicable only to a specific… Elemental analyzer manufacturer As for the operating instructions of the manufactured instrument, other usage methods will depend on the specific brand. Alternatively, you can arrange for the manufacturer to send a technician to your site for professional guidance.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >