[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Is the radiation from a coating thickness gauge significant?
发布时间: 2022-07-22 09:41
Coating thickness gauge It is a kind of we in Analytical testing instruments A commonly used instrument, many people worry about radiation when purchasing it. Today, we’ll address the question of whether coating thickness gauges emit significant radiation. To put it simply, here’s a brief overview—those interested can learn more!

1. When choosing a coating thickness gauge, it’s important to understand its operating principle. X-ray technology is also a good option. Nowadays, with proper safety measures in place, radiation concerns are largely negligible. If you’re still uneasy, you can purchase a nuclear radiation meter to measure radiation levels; the most affordable models cost only a few hundred yuan and are perfectly adequate for everyday use.
2. Compared to X-coating thickness gauge In short, magnetic‑flux‑gate thickness gauges are radiation‑free and offer high accuracy. They are handheld, making them extremely convenient, and their radiation concerns are negligible.
3. The primary principle of the X‑ray coating thickness gauge is magnetic‑field measurement. It does emit a certain level of radiation, but it poses minimal risk to human health. Appropriate protective measures have been implemented to significantly reduce radiation exposure.
4. As for ultrasonic thickness gauges, in principle, ultrasound does not involve ionizing radiation; it is a type of mechanical vibration wave. However, prolonged exposure to ultrasound can cause slight heating of human tissues; the higher the frequency, the more pronounced the heating, which may lead to the thermal degradation of water molecules within the body and damage to surrounding tissues—conditions that become hazardous over time. Therefore, high‑power, high‑intensity ultrasound remains harmful to humans.
5. In general, most thickness gauges use cesium‑137 as the gamma-ray source. Because this radionuclide has a long half-life (over 30 years) and low energy (0.51 MeV), the associated radiation protection is acceptable. Typically, at a distance of 2–3 meters from the stored source, the external gamma dose rate falls within a relatively safe range; beyond about 4–5 meters, it is essentially at background levels. Ultrasonic thickness gauges do not produce ionizing radiation, and magnetic‑particle thickness gauges may generate a very small amount, but only in negligible quantities.
In summary, coating thickness gauges generally emit very little radiation. With the exception of X-ray fluorescence thickness gauges, other types do not emit ionizing radiation. X-ray thickness gauges are equipped with shielding to protect against X-rays and comply with relevant standards. For specific data, please consult the manufacturer. Don’t worry—just like with mobile phones, everyone is aware of the radiation, yet we all continue to use them.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.