[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
What will be the future technological development roadmap for gas chromatographs?
发布时间: 2022-07-20 09:47
Due to the limitations of electronic technology and materials science, early gas chromatographs constrained the creativity and progress of designers, thereby imposing significant restrictions on chromatographic techniques at the time. The available technical approaches were cumbersome and impractical. With advances in electronics and materials science, not only have the capabilities of gas chromatographs been enhanced, but the range of applications and methodologies for this technology has also been greatly expanded, accelerating its development. Building on this trend, the author examines what the future may hold. Gas chromatograph What will the future technology roadmap look like?

1. Computers have become standard equipment.
With the widespread adoption of computer technology and the continuous decline in computer prices, computers are set to become standard equipment for gas chromatographs. The conventional control panels currently found on gas chromatographs will soon be phased out, leaving only a few flow‑rate switches on the side panel. All operational parameters of the instrument’s components will be fully managed by the computer, resulting in a more compact footprint, a simpler design, and reduced costs.
2. Flexibly interchangeable functional modules
Currently, once the inlet and detector of a gas chromatograph are installed, they are difficult to disassemble or replace, as their interface components and gas‑connection fittings lack standardized specifications and their designs do not account for frequent removal. In the future, the inlet and detector modules will adopt a unified square‑shaped interface, enabling users to easily plug in and unplug them and select different operating conditions. The plug‑in air‑connection port is located at the bottom of the module and is secured by a tightening nut on the top.
3. Data Acquisition Network Card
The various high‑cost data acquisition cards currently offered by the company will gradually be phased out, replaced by computer network interface cards. Measurement data is transmitted to the computer via Ethernet, further reducing instrument costs.
4. A shareable control software is available.
Currently, the workstations for various gas chromatographs are proprietary, meaning they can only control a specific model manufactured by a particular company. With the widespread use of electronic components, it has become possible to control instruments simply by managing electrical signals. Consequently, although gas chromatographs differ in signal formats and ranges, a single software suite that stores the signal parameters of multiple instruments can, by selecting the appropriate model, interface with devices from different manufacturers.
5. Prices have dropped sharply.
The reduction and integration of components translate into lower costs. Aside from the limited room for further price reductions in detectors, factoring in the elimination of the control panel, data acquisition cards, and the compact design of other components, the overall system— including the computer—can be expected to see its price cut by at least roughly 50%.
The above outlines predictions regarding the future technological development roadmap of gas chromatographs. If you would like to learn more about… Gas Chromatography Instrument Information Yes, you may continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.