[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Measurement methods for coating thickness gauges!
发布时间: 2022-07-15 10:46
With the continuous advancement of technology, particularly following the introduction of microcomputer technology in recent years, X-ray coating thickness gauge Its application has taken a major step toward miniaturization, intelligence, multifunctionality, high precision, and practicality. The measurement resolution has reached 0.1 micrometer, and the accuracy has improved significantly to 1%. So… Coating thickness gauge What is the measurement method? Let’s briefly discuss this issue below!
A coating thickness gauge measures the thickness of metallic films such as coatings by detecting the intensity of the second‑order X‑rays reflected from the sample after X‑rays are directed onto it. Since the instrument does not make physical contact with the sample and delivers only about 45–75 W of X‑ray power, it causes no damage to the specimen. Moreover, measurements can be completed in as little as 10 seconds to a few minutes.
The main measurement methods for coating thickness gauges include: wedge‑cutting, optical intercept, electrochemical, differential‑thickness, gravimetric, X‑ray fluorescence, beta‑backscatter, capacitance, magnetic, and eddy‑current techniques. There are many others as well. Among these, the first five methods are destructive; they are cumbersome, relatively slow, and are typically used for sampling inspections.
X-ray and beta‑ray methods are non-contact, non-destructive measurement techniques with a limited measurement range. The X-ray method can measure extremely thin coatings, bilayer coatings, and alloy coatings. The beta‑ray method is suitable for measuring coatings and substrates with atomic numbers greater than 3. The capacitance method is used exclusively to measure the thickness of thin insulating coatings on conductive substrates.
Coating thickness gauge measurement method:
1. When X-rays irradiate a sample, the signal returned after passing through the coating–substrate interface exhibits a sharp change. For an infinitely thick sample, the backscattered intensity is theoretically identical to that of a single-layer material with the same composition. In practice, it is difficult to distinguish two layers containing the same elements, as their signals cannot be resolved.
2. XRF coating thickness gauge :
Commonly referred to as X-ray fluorescence thickness gauges, coating thickness gauges, thin-film thickness gauges, gold‑nickel thickness gauges, electroplated‑film thickness gauges, and the like.
Function: Precisely measures the thickness of metal coatings.
Scope of application: Measures the thickness or composition of coatings, platings, thin films, and liquids, with a range from 22 (Ti) to 92 (U).
The above is an introduction to the measurement methods for coating thickness gauges. Coating thickness measurement has become a critical step in the manufacturing industry and in assessing surface‑quality standards, serving as an essential means of ensuring that products meet specified quality requirements. Precise specifications are in place for coating thickness. With its broad applicability, wide measurement range, user‑friendly operation, and affordable price, this instrument is widely employed in both industrial settings and scientific research. If you have such a need, please contact us!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.