[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
X-ray fluorescence spectrometer manufacturer!
发布时间: 2022-07-12 09:11
Shenzhen Depu Instrument Co., Ltd. is a company engaged in sales, manufacturing, and research and development. X-ray fluorescence spectrometer manufacturer , developed in-house by Depu DX Series Fluorescence Spectrometer It is a multi-purpose… Spectrometer By employing a core precision algorithm and low-light aggregation technology, it not only retains the capability to measure the thickness of thin films on tiny samples and in recessed areas but also meets the requirements for RoHS compliance testing and elemental analysis.
Performance advantages of DePu’s X-ray fluorescence spectrometers:
1. Microsample analysis: minimum measurement area
2. Zoom‑adjustment algorithm: Enables adjustment of the measurement distance to analyze non‑uniform samples, with a zoom range of 0–30 mm.
3. State-of-the-art precision algorithm: It can accurately measure Li(3)-U(92) elemental coatings, multilayered multi-element structures, and even different layers of the same element.
4. Advanced spectrometric technology: reduces interference from elements with similar energy levels and lowers the detection limit.
5. High-performance detector: SDD silicon drift detector with a window area of 25 mm².
6. X-ray apparatus: a microfocus-enhanced X-ray tube with a focusing device.
The thickness gauge optical‑path switching device developed by Despu Instruments aligns X‑ray and visible‑light imaging on the same vertical axis, integrating visual inspection with test positioning while minimizing X‑ray divergence. Paired with dedicated software, it enables focus and zoom functions, accommodating samples of various shapes, heights, and surface irregularities. The highly integrated optical‑path switching mechanism allows the angle between the beam path and the detector to be doubled, thereby reducing errors caused by arc‑shaped tilting during alignment, and enabling characteristic X‑rays to penetrate and analyze relatively thick surface layers.
Algorithm
Building on the Alpha and Fp methods, an advanced R&D team has iteratively developed core algorithms that perform multi‑parameter optimization—accounting for primary fluorescence, secondary fluorescence, target fluorescence, absorption‑enhancement effects, and scattering background—for each element in the sample. Coupled with optical‑path switching technology, a zoom‑type structural design, and a robust multi‑channel pulse‑analysis acquisition system, the instrument requires only a small number of standard samples to calibrate its instrument response factors, enabling precise analysis of repetitive coatings, non‑metallic materials, light metals, multilayered multi‑element systems, and organic layers.
As a manufacturer of X-ray fluorescence spectrometers, Despu Instruments currently serves numerous enterprises. We warmly welcome your company to inquire about our X-ray fluorescence instruments and are committed to providing you with dedicated, top‑notch service.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.