How to Use an X-ray Fluorescence Spectrometer!
发布时间: 2022-07-08 09:45
In recent years, X-ray fluorescence spectrometer Its application scope continues to expand across various industries, making it indispensable in metallurgy, geology, non‑ferrous metals, building materials, commodity inspection, environmental protection, and public health—particularly in the field of RoHS testing. It can analyze most elements and accommodate a wide range of sample types, including solids, powders, fusion beads, and liquids, with an analytical range spanning from beryllium (Be) to uranium (U). Key features include rapid analysis and broad elemental coverage, along with minimal measurement interference. Next, we will explain X‑ray analysis. Fluorescence spectrometer How to use it!

1. Start
1.1 If the shutdown lasts 2 to 8 hours, the external chilled water system shall be run for 10 minutes first, and the internal chilled water system for 5 minutes; if the shutdown exceeds 8 hours, the external chilled water system shall be run for 15 minutes first, and the internal chilled water system for 10 minutes.
1.2 The startup sequence is to turn on the external cooling water.
1.3 Turn on the internal cooling water (COOLER) switch.
1.4 Turn on the CTROL and VACUUM switches (verify that the vacuum level has dropped below 10, and confirm that the conductivity of the internal cooling water is also below 10).
1.5 Turn on the HEATER
1.6 Open the panel high-voltage switch
1.7 Turn on the computer, launch the MXF software, click “Monitor,” observe the status, and verify that the device is online.
1.8 Once everything is functioning normally, turn on the X-ray switch located at the bottom right of the panel.
1.9 Click the X‑RAY ON button at the top left of the panel to activate the X‑ray system, then increase the tube current and tube voltage in the following sequence: (5 kV–0 mA) → (10 kV–mA) → (15 kV–0 mA) → (20 kV–0 mA) → (20 kV–5 mA) → (20 kV–10 mA). If the equipment is shut down for 2 to 8 hours, wait 10 minutes between each step; if the shutdown exceeds 8 hours, wait 20 minutes between each step.
1.10 Click the “Maintenance” tab—this will bring up the Maintenance-MXF window. Then click “Instrument Setup”—the Instrument Setup screen will appear. Under the X-ray tube voltage and tube current fields, set both values to 30 kV and 20 mA, respectively. Click “Execute” to restore the X-ray tube to its standby state, enabling routine analytical operations.
2. Shut down
When the voltage is normal and shutdown debugging or other operations are required, a standard shutdown procedure may be performed.
2.1 In standby mode, the tube voltage is set to 30 kV and the tube current to 20 mA. To shut down the system, click the “Maintenance” tab; the Maintenance‑MXF window will appear. Then select “Instrument Setup,” which will open the Instrument Setup screen. Under the X-ray section, adjust the tube voltage and tube current settings as follows: (20, 10) → (20, 0) → (10, 0) → (0, 0), finally returning both values to zero.
2.2 When both the tube voltage and tube current have been set to zero, the system can be shut down. Switch the X‑RAY control on the panel to OFF.
2.3 Turn off the X-ray switch below.
2.4 Turn off the HEATER
2.5 Closing Plate High-Voltage Switch
2.6 Turn off the CONSOLE and VACUUM switches
2.7 Close the MXF editing software on the computer, then shut down the computer.
2.8 If it is necessary to shut down the internal circulation water, wait for 5 minutes before doing so; if not necessary, do not shut it down. If it is necessary to shut down the external circulation water, wait for 10 minutes before doing so; if not necessary, do not shut it down.
2.9 Turn off the switch on the distribution box to completely de-energize the instrument, enabling maintenance and inspection procedures.
The above is an introduction to the operation of X-ray fluorescence spectrometers. If you have any instrument requirements—for elemental analysis, RoHS testing, or other applications—please feel free to contact us online or by phone, and we will respond to you promptly!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.