[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Sample analysis procedure for liquid chromatography!
发布时间: 2022-07-04 10:25
Liquid chromatograph With the help of High-performance liquid chromatography Its theories and principles encompass new technologies such as small-particle packing materials, extremely low system volumes, and rapid detection methods, thereby enhancing analytical throughput, sensitivity, and chromatographic peak capacity. This instrument not only delivers ultra‑fast analysis speeds and superior resolution but also enables both conventional and high‑pressure HPLC analyses on a single platform, offering greater sensitivity and flexibility. So, what are the sample‑injection steps for a liquid chromatograph? Let’s take a brief look below!
The sample analysis procedure for a liquid chromatograph consists of three steps:
Liquid chromatography sample preparation step 1: Decompose and classify the product or sample to be analyzed.
According to the standard, the sample or product under test is disassembled into an average sample that cannot be further separated by mechanical means. The average sample is then classified by material into: plastic matrix, metal‑matrix, aluminum‑magnesium matrix, and solder matrix.
Liquid chromatography sample analysis step two: Classify the test samples into fractions.
Based on the categorized samples, plastic matrix samples are analyzed using XRF to detect Pb, Cd, Hg, Cr, and Br, while a RoHS 2.0 tester is used to measure four phthalate esters; a comprehensive assessment indicates that these samples exceed the regulatory limits. For other sample types, XRF‑W7 is employed directly to determine the levels of Pb, Cd, Hg, Cr, and Br, enabling an immediate determination of whether the limits are exceeded.
Liquid Chromatography Sample Analysis Step 3: Procedure for Determining Four Phthalate Esters in Organic Plastics
Weigh a specified amount of the sample to be analyzed according to the standard, and process it into the prescribed fine particles using the standard method. Weigh 0.5 g (accurate to 0.1 mg) of the prepared fine particles, dissolve them in an organic solvent, perform ultrasonic extraction, followed by sieving and separation, to obtain the extract solution for analysis.
Meanwhile, four邻苯 standard samples were weighed, and the reference materials GBW(E)082722 or GBW(E)082723 were used. The same dissolution procedure was employed for both dissolution and ultrasonic extraction. During the initial handover training, the engineer, in collaboration with the technical staff, prepared standard solutions of ophthalmic compounds and PBB/PBDEs, established the analytical conditions, analyzed the standard solutions, and constructed the calibration curves.
Set the volume of the sample to be analyzed, inject it into the instrument using a syringe, and press the start button. After approximately 15 minutes, the instrument will display the test spectrum and relevant parameters. Based on these parameters and the relationship between peak area and concentration, calculate the analyte concentration in the sample. Using the same procedure, determine the ratio K between the measured value of the standard sample and its certified value; use K as an internal‑standard correction factor to compute the final result for the sample under analysis.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
