News Center

News Center

Principle of a precious metal detector!

发布时间: 2022-07-04 10:15

Precious Metal Analyzer Also known as a precious metal tester, it belongs to… Fluorescence spectrometer one type, more precisely, belongs to X-ray fluorescence spectrometer A small subcategory. Here, the editor will briefly explain the working principle of a precious-metal detector:

1) Definition of a standard curve: In analytical experiments, the standard curve method is commonly used for quantitative analysis, and the standard calibration curve is typically a straight line.

2) Purpose of the calibration curve: X-ray fluorescence spectroscopy is a reference method. Quantitative analysis of samples requires standard materials; therefore, a standard calibration curve must be constructed. The calibration curve is established by first preparing a series of standard samples to generate a calibration relationship, which is then used to calculate and interpret the measurement results.

3) Principle of the calibration curve: For the XRF standard‑curve method, constructing a calibration curve requires multiple standard samples with known concentrations. These standards are then analyzed, yielding signal intensity values that serve as the x‑axis, while the corresponding concentration values form the y‑axis. After configuring the calculation parameters, the concentration values are entered, with concentration on the y‑axis. Using the software’s algorithm, the intensity–concentration data are fitted to generate the calibration curve.

After constructing the calibration curve, the instrument‑measured signal can be converted into the analyte concentration when analyzing samples.

4) Definition of a reference material: A reference material, also known as a standard substance, has properties that have been certified by an accredited organization or the public and is used to calibrate instruments and determine the value of samples or materials.

5) Requirements for standard samples in X-ray fluorescence spectroscopy:

Ø The sample content is accurate and reliable, with standard reference materials used; the physical properties of the standard samples are consistent with those of the samples to be analyzed.

Ø Standard samples must exhibit stable physical properties; samples with internal compositional segregation, rough surfaces, or surface degradation due to oxidation are not permitted.

Ø A series of standard samples with multiple concentrations is available, and the concentration range should encompass both the maximum and minimum elemental concentrations found in the sample.

 

The operating principle of a precious-metal analyzer is also based on spectroscopic techniques—specifically, X-ray fluorescence—to determine the purity of gold and silver. It is suitable for use in gold and silver jewelry stores, pawnshops, quality‑inspection agencies, and other related industries. The Xifan gold‑and‑silver assay instrument, which employs camera‑based positioning technology, has been adopted in the jewelry sector. This camera‑assisted positioning system not only makes gemstone and metal analysis more intuitive but also ensures that X‑ray fluorescence is precisely focused on the target area. Furthermore, it can correlate the detected exact location with corresponding images of the test results and generate a printed report that includes both the findings and the calculated data.


The Dapu spectrometer refers to X-ray fluorescence spectroscopy, an advanced technique for analyzing precious metals. When atomic electron shells are excited by high-energy X-rays, electrons outside the nucleus undergo transitions, emitting secondary X-ray energy in the process. The energy emitted by each element exhibits distinct characteristics; the detection system quantifies these energies and intensities to determine the elemental composition.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >