[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
What parameters can a RoHS 2.0 tester measure?
发布时间: 2022-06-30 10:22
Starting from July 22, 2019, the European Union has mandated RoHS testing for ten categories of products. The new RoHS regulation is part of Directive 2011/65/EU, which forms an integral component of CE marking. Products intended for direct entry into the European market must obtain RoHS 2.0 certification (CE‑RoHS certification). The updated RoHS framework includes both RoHS testing and RoHS certification—namely, a RoHS certificate and a RoHS test report—so… RoHS 2.0 detector What tests can be performed? Let’s take a quick look!
The RoHS 2.0 detector can test the following substances, as specified in Directive 2011/65/EU (RoHS 10): lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium (Cr6+), polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs); as well as di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), and di(2-ethylhexyl) phthalate (DEHP). Specifically, DEHP is limited to 1,000 ppm, BBP to 1,000 ppm, DBP to 1,000 ppm, and DIBP to 1,000 ppm.
I. Performance Characteristics of the RoHS 2.0 Detector
Bottom illumination: Meets the testing requirements of samples with various shapes.
Collimators and filters: Electric switching among various collimators and filters to accommodate a wide range of testing methods.
Mobile platform: A precision manual translation stage for convenient positioning of test points.
High-resolution detector: enhances analytical accuracy
Next-generation high-voltage power supply and X-ray tube: stable and reliable performance, with up to 50 W of power for enhanced testing efficiency.
II. Technical Specifications of the RoHS 2.0 Detector
Elemental analysis from sulfur (S) to uranium (U)
The analytical detection limit is as high as 1 ppm.
The analyzed content typically ranges from 1 ppm to 99.99%.
Any number of optional analysis and recognition models
Independent matrix-effect correction model
Multivariate nonlinear regression process
The temperature adaptation range is 15°C to 30°C.
Power Supply: AC 220V ±5V; it is recommended to use an AC line‑conditioning, regulated power supply.
Energy resolution: 160 ± 5 eV
External dimensions: 550×416×333 mm
Sample chamber dimensions: 460 × 298 × 98 mm
Weight: 45 kg
III. Standard Configuration of the RoHS 2.0 Tester
Mobile sample platform
Electrocooled Si-PIN Detector
Signal Detection Electronic Circuit
High- and low-voltage power supply
High-power X-ray tube
Computer and inkjet printer
IV. Application Areas of Testing Items for RoHS 2.0 Analyzers
RoHS Testing and Analysis
Composition analysis of geological minerals and alloys (such as copper, stainless steel, etc.)
Measurement of metal coating thickness, and determination of plating bath and coating compositions.
Analysis of the content of precious metals such as gold, platinum, and silver, as well as various jewelry items.
The above is an introduction to the types of substances that a RoHS 2.0 detector can measure. If you have… RoHS 2.0 instrument If you have any inquiries, please feel free to contact us online. We will get in touch with you promptly to provide a quotation and product information for the RoHS 2.0 tester.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.