[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
How do you use a high-quality precious-metal detector?
发布时间: 2022-06-30 10:00
Of excellent quality Precious metal detector How do you use it? Many people probably have this very question. Below, we’ll briefly explain how to use this high‑quality product. Metal detector How do you use it!
1. Place a sterling silver plate on the instrument to initialize it; during initialization, all other buttons on the software interface are disabled. Initialization restores all system settings to their default values and ensures that each element is correctly aligned with its corresponding energy channel. (After placing the sterling silver plate, click the “Initialize” button on the software interface; the instrument will perform the initialization automatically. Upon completion, the interface will display either a success or failure message. If initialization fails, restart the instrument and repeat the process until it succeeds.)
2. Select the template name corresponding to the sample to be tested to ensure accurate and reliable results. During testing, the instrument automatically calculates and controls the test duration. (After placing the sample correctly, click the “Test” button on the software interface; the instrument will automatically begin analyzing the sample. Once the test time is complete, the results will be calculated automatically, and a test report will pop up. To stop the test prematurely, simply click the “Stop” button.)
3. During testing, invoke the pure-element virtual spectrum to verify that the spectral peaks of the sample being analyzed are normal; for example, when analyzing gold, use the virtual spectrum of pure gold (Au), and when analyzing platinum, use the virtual spectrum of pure platinum (Pt). In the spectral display area, right-click; a menu will appear, allowing you to select and open the corresponding pure spectrum for the sample under test. When testing other samples, delete any previously used virtual spectra from the interface and then load their respective virtual spectra.
4. When testing a sample, you can choose to enter the sample name or leave it blank. If you wish to save your sample’s test results for future reference, simply select this option in the software interface. If you do not need to save the results, leave this option unchecked.
5. When you need to view the test results of a previously saved sample, simply click on the interface to locate the sample name, select it, and open it—then tap the software interface to view the sample’s test results.
6. After the sample has been tested, the test results will automatically appear below the calculation report. The test report can be printed or left unprinted. Perform testing on such samples.
The above is an introduction to how to use a high‑quality precious‑metal detector. If you have any needs for such a device, please contact us online or send us an inquiry—we’ll promptly provide you with a quote and other product details!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.