Operating procedures for a gas chromatograph!
发布时间: 2022-06-27 10:05
Gas chromatograph The operating procedures include the power-on sequence, standard sample procedure, residual‑quantity check (solvent‑residue measurement), purity check (solvent‑purity testing), and the power‑off sequence.

I. Power-On Procedure:
1. Open the nitrogen, air, and hydrogen valves.
2. Turn on the gas chromatograph’s power switch.
3. Set the temperatures of the injector, oven, and detector.
4. Turn on the computer workstation and open the oven, then minimize it.
5. When the injector, oven, and detector have reached 150°C, 65°C, and 150°C, respectively, click STARTD, then ignite the flame.
II. Reference Sample Procedure:
1. Pipette 1 mL of each reagent into the vial, mix well, then dispense 1 µL of the solution onto the vial wall. Place the vial in an 80°C oven for 30 minutes, remove it, and withdraw 1 mL of gas. Inject this gas into the gas chromatograph’s inlet while simultaneously clicking STARTD.
2. After data acquisition is complete, click Stop, then click Save to the D drive as a standard image, and simultaneously click Start. Click General Settings, set the minimum peak height to 1 and the minimum peak area to 5, then click OK. Click Automatic Peak Search, then set the Quantitative Method to Area External Standard Method. Select all peaks in the sequence, check for any extraneous peaks, and do not select them. Enter the name of each component, input the concentration for each (Component Content = 1/Component Number × Density × Purity × 100), click Clear No Archive, click OK, click Current Table Archive, click OK, and then click OK again. Click Work Curve, select a component group, click Calibration, and then click OK. In the current window, save the method parameters as a template, enter a file name, and save.
3. Residual Quantity Inspection (Solvent Residue Measurement) Procedure:
1. Open the sample file image, select the sample you wish to view, and click Open. (Once data acquisition is complete, click Stop, then save the sample image to drive D, and click STARTD.) Next, go to General Settings, set the minimum peak height to 0.1 and the minimum peak area to 1, click OK, and then select Automatic Peak Search. In the current window, click Import Method Parameter Template, open the standard sample image, click Quantitative Calculation, and then click Print Preview.
IV. Purity Testing (Solvent Purity Test) Procedure:
1. Open the sample file image, select the sample you wish to view, and click Open. (Once data acquisition is complete, click Stop, then save the sample image to drive D, and click STARTD.) Next, go to General Settings, set the minimum peak height to 0.1 and the minimum peak area to 1, click OK, and then select Automatic Peak Search. In the current window, click Import Method Parameter Template, open the standard sample image, choose Quantitative Method, select Area and Normalization, click OK, proceed to Quantitative Calculation, and finally click Print Preview.
V. Shutdown Procedure:
1. Turn off the temperatures of the injector, column oven, and detector.
2. Shut off the hydrogen and air.
3. When the temperatures of the injector and detector fall below 80°C, turn off the power switch of the gas chromatograph.
4. Shut off the nitrogen and perform 6S activities.
According to China’s data‑collection protocols and relevant standards, the primary parameters for testing and controlling pharmaceutical packaging and materials include sealing performance, barrier properties, surface smoothness, mechanical properties, residual solvent levels, thickness, cap torque, headspace gas analysis, print quality, and others. Each of these testing parameters requires a corresponding analytical instrument.
The above is about the gas phase. Chromatograph An introduction to the operating procedures is provided. If you have any related product needs, please feel free to consult us online or contact us directly. We will get in touch with you promptly to provide pricing and other product information.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.