RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
How to use a halogen detector!
分类: News Center
发布时间: 2022-06-23 11:12
An instrument used to detect leaks of all halogen gases at a specified level is called Halogen detector High‑quality halogen leak detectors are stable and highly sensitive, embodying the very essence of leak‑testing instruments. However, any instrument can only perform as intended when operators master the correct procedures. Let’s now take a look at how to use a halogen leak detector.
What is the method for using a halogen detector?
1. Power-on and Preheating Procedure: Turn on the computer and the instrument’s power supply. Double-click the halogen detector icon on the desktop to log in and create an account. After logging in, open the high-voltage power supply in the settings dialog, gradually increase the tube voltage and tube current, confirm the settings, and then preheat the instrument for approximately 30 minutes until both the tube voltage and tube current reach their set values.
2. Calibration and Testing Procedure: Open the top cover of the halogen detector, insert the silver calibration film, and then click “Fine Adjustment” to calibrate the instrument. Next, turn on the instrument, place the sample to be tested inside, enter the sample information, select the test conditions, and press the “Start Measurement” button to begin the analysis.
3. Testing and Report Generation Process After the test sample has been analyzed, the halogen analyzer’s software automatically generates a test report based on the report format defined by the calibration curve. The resulting report can be conveniently saved as an electronic document for historical record‑keeping and retrieval, or printed out for archival purposes.
4. Procedure for Shutting Down the Instrument After all tests on the halogen detector have been completed, click the “Close” button to exit the software. Note that the hardware may only be powered off once the software has been properly closed. By following these four steps, you can clearly master each stage of operating the halogen detector. However, professional halogen detectors require trained personnel to operate them, and they must be used according to the prescribed procedures and schedules, as any improper handling could compromise test results and shorten the instrument’s service life. Therefore, exercise caution when using the device.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.