The working principle of a chromatograph!
发布时间: 2022-06-23 10:52
Chromatographic analysis is a technique used to separate and analyze multi-component mixtures. It primarily exploits differences in the boiling points, polarities, and adsorption coefficients of the components in the sample to achieve separation within the chromatographic column, followed by qualitative and quantitative analysis of the separated constituents.

Chromatograph These include partition chromatography, adsorption chromatography, ion-exchange chromatography, and gel filtration chromatography, among others. Their operating principles are summarized as follows:
I. Working Principle of the Distribution Chromatograph:
Separation is based on the differences in solubility of sample components in a liquid stationary phase.
II. Working Principle of the Adsorption Chromatograph:
Separation is achieved by exploiting the differing adsorption capacities of sample components on an adsorbent (the stationary phase).
III. Principle of Operation of Ion Exchange Chromatography Instruments
Separation is achieved by exploiting the differing affinities of sample components for the ion-exchange resin (the stationary phase).
IV. Working Principle of Gel Chromatography
Separation is achieved by selectively permeating molecules of different sizes through a porous stationary phase.
A gas chromatograph uses a gas as the mobile phase (carrier gas). When the sample is introduced into the injector and vaporized, it is carried by the carrier gas into either a packed column or a capillary column. Due to differences in boiling points, polarities, and adsorption coefficients among the components of the sample, these components are separated within the chromatographic column. A detector mounted at the column outlet then sequentially detects each component based on its physicochemical properties, ultimately transmitting the converted electrical signals to the chromatography workstation. The workstation records and analyzes the resulting gas chromatograms, yielding quantitative and qualitative results for each constituent. A schematic diagram of the operating principle is shown below:
Due to its high separation efficiency, rapid analysis speed, and minimal sample consumption, this analytical method has been widely adopted in the petrochemical, biochemical, medical and health, sanitary quarantine, food inspection, environmental protection, food industry, clinical settings, and other sectors. In these fields, gas chromatography addresses critical challenges such as quality control of industrial intermediates and finished products, scientific research, pollutant detection, and production process monitoring.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.