[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
DePu Instruments’ RoHS testing solution!
发布时间: 2022-06-22 14:29
DePu Instruments is a professional manufacturer of analytical instruments. Previously, we’ve focused mainly on direct-reading spectrometers; this time, however, we’re here to share insights on how to address issues related to the manufacturer’s… RoHS Testing Plan Currently, RoHS has been updated to version 2.0. Under the original RoHS 1.0, electrical and electronic products were subject to restrictions on six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers—with a maximum lead content of 0.1%. Subsequently, RoHS 2.0 introduced additional restrictions on four phthalate plasticizers—DIBP, DEHP, DBP, and BBP—each with a limit of 0.1%.
X-ray Fluorescence Spectrometer Series
DePu Instruments X-ray fluorescence spectrometer It has been established as a rapid and convenient screening method, enabling precise analysis of elements such as lead (Pb), mercury (Hg), cadmium (Cd), chromium (Cr), and bromine (Br). Currently, our X-ray fluorescence spectrometer lineup includes the EDX-6000 X-ray fluorescence spectrometer, the EDX-9000 vacuum‑type XRF spectrometer, and the fast, handheld XRF RoHS detector. Customers can select the model that best meets their specific requirements.
X-ray fluorescence spectrometry, or XRF, is a physical elemental analysis technique that offers distinct technical advantages, including speed, non‑destructiveness, simultaneous multi‑element analysis, and low analytical costs. It plays a key role across numerous industries, such as electronics, electrical appliances, jewelry, toys, food, construction materials, metallurgy, mining, plastics, petroleum, chemicals, and pharmaceuticals. The method can analyze elements ranging from sulfur (S) to uranium (U), with sample types encompassing solids, liquids, and powders. It is also employed to comply with the EU RoHS directive for detecting hazardous substances—lead (Pb), mercury (Hg), cadmium (Cd), and hexavalent chromium (Cr)—as well as with halogen‑free regulations for halogen detection. Additionally, it supports testing for eight heavy metals restricted in sectors like toys: cadmium (Cd), lead (Pb), mercury (Hg), chromium (Cr), antimony (Sb), arsenic (As), barium (Ba), and selenium (Se).
High-performance liquid chromatograph
of Despu Instruments High-performance liquid chromatograph It can achieve the separation and qualitative and quantitative analysis of most organic compounds. The primary analytes range from polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) under RoHS 1.0 to four newly added phthalates under RoHS 2.0: bis(2-ethylhexyl) phthalate (DEHP), benzyl butyl phthalate (BBP), dibutyl phthalate (DBP), and diisobutyl phthalate (DIBP).
The main applications include the accurate detection of organic compounds specified in the RoHS 2.0 Directive, namely: ① di(2-ethylhexyl) phthalate (DEHP), ② butyl benzyl phthalate (BBP), ③ dibutyl phthalate (DBP), ④ diisobutyl phthalate (DIBP), ⑤ polybrominated biphenyls (PBB), and ⑥ polybrominated diphenyl ethers (PBDE); as well as phthalates defined under the REACH Regulation, formaldehyde under the EN 71 Toy Safety Directive, and polycyclic aromatic hydrocarbons; additionally, compounds such as 4-chlorotoluene, 5-chlorotoluene, bisphenol A, azo dyes, and aromatic amines.
That concludes our RoHS testing solutions provided by Despu Instruments.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.