[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Introduction to one of the elements detected by RoHS testing instruments: polybrominated biphenyls!
发布时间: 2022-06-20 13:45
Polybrominated biphenyls (PBBS) are another important hazardous substance covered by the RoHS Directive, which stipulates that their concentration in the tested material must be below 1,000 ppm, or 0.1%. So what exactly is this substance? Today, we’ll discuss it. RoHS detector One of the elements being tested is polybrominated biphenyl!

Polybrominated biphenyls (PBBs) comprise 209 congeners, including tetra-, penta-, hexa-, octa-, and decabrominated compounds, and are typically marketed as a mixture of biphenyls with varying numbers of bromine atoms. When sold as commercial products, they are collectively referred to as polybrominated biphenyls.
On October 27, 2017, the International Agency for Research on Cancer of the World Health Organization released a preliminary compilation of its list of carcinogens for reference, in which polybrominated biphenyls were classified as Group 2A carcinogens.
Polybrominated biphenyls belong to the class of brominated flame retardants (BFRs). Brominated flame retardants are widely used industrial chemicals, commonly found in printed circuit boards, plastics, coatings, wires and cables, and resin‑based electronic components. Polybrominated biphenyls are also persistent organic pollutants (POPs), characterized by long environmental persistence, resistance to degradation, low volatility, and a propensity to bioaccumulate in organisms and human adipose tissue. They can cause adverse effects such as damage to the brain and nervous tissues; photochemical degradation represents one of the major pathways for their fate in the environment.
As the global economy recovers and living standards continue to rise, the production and consumption of electronic and electrical products are steadily increasing, driving a corresponding rise in the output of polybrominated biphenyls as flame retardants. With the phase-out and disposal of these products, pollutants such as polybrominated biphenyls and polybrominated diphenyl ethers have become a serious environmental concern. Trace amounts of PBBs have been detected in soils and other environmental media.
Hazards of polybrominated biphenyls:
According to studies on polybrominated biphenyls, rhesus monkeys exhibit the greatest sensitivity to their toxicity. Long-term administration of 1.3–300 mg/kg of polybrominated biphenyls to rhesus monkeys results in weight loss, hair loss, skin lesions, and edema. Research indicates that repeated exposure to low doses of polybrominated biphenyls can induce morphological changes in rats, including increased liver weight and size, hepatocyte swelling, endoplasmic reticulum proliferation, and hepatocellular necrosis; it may also lead to a reduction in thymus weight and volume, accompanied by mild atrophic alterations.
Long-term in vitro toxicity studies have shown that PBB can induce liver tumors; rats and mice exposed to 0.5 and 5 mg/(kg·d) of PBB2a, respectively, for 18 months exhibited an extremely high incidence of hepatocellular carcinoma. PBB also exerts adverse effects on reproduction. For example, when rhesus monkeys were fed PBB at a dose of 0.01 mg/(kg·d) for 12.5 months, a reduction in the fertility of their offspring was observed.
Mode of infection:
Direct contact
Generally, those who are directly exposed to polybrominated biphenyls are primarily production workers, and the vast majority of the polybrominated biphenyl dust they encounter daily is eliminated from the body. However, with daily accumulation, the amount stored in the body gradually increases.
Indirect contact
Trace amounts of polybrominated biphenyls in the atmosphere, water, and soil can ultimately enter the human food chain, or they may adhere to atmospheric particulate matter—particularly PM10 and PM2.5—and be inhaled into the body. Consequently, for most people, exposure to polybrominated biphenyls occurs primarily through dietary intake.
How to prevent exposure to polybrominated biphenyls:
a. Continuously conduct public outreach and education to enhance the public’s awareness of the need for proactive prevention regarding the significant environmental hazard posed by polybrominated biphenyls, a class of persistent organic pollutants.
b. Ensure food safety.
c. Workers who have direct contact with polybrominated biphenyls (such as those involved in the production of brominated flame retardants) should pay particular attention to food safety: they should avoid eating in open-air or contaminated environments and must wash their hands thoroughly before meals.
d. Minimize pregnant women’s and infants’ exposure to electronic and electrical devices.
e. Develop environmentally friendly flame-retardant materials to replace polybrominated biphenyls.
If you require a RoHS‑compliant detector for polybrominated biphenyls, please feel free to consult us online or call us. We will promptly provide you with the relevant product specifications and other details.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.