[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Precautions for Metal Element Detection and Analysis Instruments!
发布时间: 2022-06-16 10:28
Metal Element Detection and Analysis Instrument It can detect available trace elements in soil and plant tissues, including copper, iron, manganese, zinc, calcium, and magnesium. So, what are the precautions for using a metal‑element analyzer? Let’s take a look below!

Precautions for Metal Element Detection and Analysis Instruments:
1. The room where acetylene cylinders are stored must be well-ventilated, and no open flames are permitted indoors.
2. The outlet pressure of acetylene cylinders shall not exceed 0.12 MPa.
3. When the flame is extinguished, first shut off the acetylene cylinder. After the flame has gone out, press the “Test” button in the workstation’s flame atomizer parameter settings until any residual acetylene gas in the tubing has been purged.
4. Open flames are prohibited in the operating room of the AA4530F instrument, and acetylene cylinders must not be stored in the same room as the instrument.
5. When igniting the instrument, the acetylene flow rate should not exceed 3 L/min, and ensure that the waste liquid line is equipped with a water seal prior to ignition.
6. When starting up the graphite furnace, it must be connected to a high‑power 220 V power supply and to water and gas lines. For safety, operators must remain near the instrument after startup.
The metal element analyzer is a new-generation, comprehensive analytical instrument developed in China. With a single device, it can simultaneously determine the contents of C, S, Mn, P, Si, Cr, Ni, Mo, Cu, Ti, V, Al, W, Mg, total rare earth elements, Co, and other elements in carbon steel, alloy steel, stainless steel, gray cast iron, ductile cast iron, heat‑resistant steel, malleable iron, wear‑resistant steel, and cast iron. It features a robust database for storing and analyzing test results, as well as convenient functions for querying working curves, modifying data, and adding or deleting calibration curves.
The metal element analyzer is equipped with a data‑logging function that can store over 500 records, including power‑off retention. Analysis results are saved in Excel spreadsheet format, allowing users to retrieve test methods and outcomes at any time. It also includes dedicated software for soil‑testing‑based fertilizer formulation and a communication module for data transmission. Furthermore, it features comprehensive safety interlock protection: the system provides automatic alarms and safeguards against continuous improper burner operation, gas leaks, insufficient air pressure, and abnormal flameout.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
