[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
What is a RoHS detector used for?
发布时间: 2022-06-14 14:24
Currently, a device has appeared on the market, called RoHS detector So, do you know what an ROHS detector is used for? Anyone familiar with the testing industry knows that environmental protection has become one of the primary concerns in modern life. With the introduction of the ROHS Directive, this ROHS detector was specifically designed to verify compliance with that directive. Now, let’s take a closer look at the specific substances covered by the ROHS Directive—then you’ll understand both the purpose of the ROHS detector and exactly what it tests for.

RoHS initially included six restricted substances: lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium (Cr6+), polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs). The maximum concentration limits are as follows: cadmium: 0.01% (100 ppm); lead, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers: 0.1% (1,000 ppm).
On June 4, 2015, the European Union published Directive (EU) 2015/863 in its Official Journal, amending the list of restricted substances in Annex II to the RoHS 2.0 Directive 2011/65/EU by adding four phthalate esters: di(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP), and diisobutyl phthalate (DIBP). With this amendment, the list of restricted substances in Annex II of the RoHS 2.0 Directive has been officially updated to ten items, namely: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), polybrominated diphenyl ethers (PBDE), di(2-ethylhexyl) phthalate (DEHP), butyl benzyl phthalate (BBP), dibutyl phthalate (DBP), and diisodecyl phthalate (DIDP), each with a maximum permitted concentration of 0.1%.
Effective date of the directive: June 24, 2015; mandatory implementation date for the four substances DEHP, DBP, BBP, and DIBP:
1. For electronic and electrical products other than those falling under Categories 8 and 9 of Annex I to the RoHS Directive, the mandatory implementation date is July 22, 2019.
2. The mandatory implementation date for Class 8 and Class 9 medical and monitoring devices is July 22, 2021.
3. Toy products are not subject to the phthalate restrictions under RoHS 2.0; however, they must still comply with the phthalate restrictions set forth in Article 51 of Annex XVII to the REACH Regulation.
4. Spare parts used for repair, reuse, functional upgrades, and capacity enhancement in cables and electrical and electronic products placed on the market before July 22, 2019, are exempt from this restriction; this also does not apply to cables placed on the market before July 22, 2021. Medical devices, including in vitro diagnostic devices, monitoring and control instruments, and industrial measurement and control equipment, are likewise excluded.
In fact, RoHS testers can not only detect compliance with the RoHS Directive; some manufacturers also integrate additional testing functions, such as coating analysis. For example, Shenzhen Despu offers a versatile RoHS tester that simultaneously meets both RoHS 1.0 and RoHS 2.0 requirements while also enabling coating‑thickness measurements. Feel free to contact us for more information.
Alright, by now you should know what an RoHS detector is and what it’s used for. If you’d like to learn more, feel free to explore our other pages!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.