[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
The workflow of a metal detector for inspecting the internal crown of dentures!
发布时间: 2022-06-13 10:33
As times advance and patients become more aware of their rights, coupled with growing mistrust of physicians, medical‑patient disputes have also increased. For example, when it comes to the authenticity of materials—such as counterfeit products—many assume that doctors are fully aware of the issue; in reality, the ultimate responsibility for such disputes rests with the physician. Of course, if a material error occurs—for instance, a case of falsification—the dental model laboratory bears 100% liability, yet the doctor’s professional reputation can still suffer. That’s why choosing a reliable dental model manufacturer is crucial. At this point… Metal detector Its role becomes evident: as a metal detector manufacturer, Despu Instruments provides metal‑detection equipment to dental‑prosthesis manufacturers, enabling them to measure the metal content in dentures and produce high‑quality substructures. Below, we will walk through the workflow of using a metal detector to inspect denture substructures.

1. After suppliers deliver the metal, incoming material inspections and sampling tests must be conducted for each batch; only materials that pass inspection may be accepted into inventory.
2. Upon receipt of the metal, the order numbers will be verified one by one against the metal item names, and barcode management will be used to track the usage of each batch of metal across different orders.
3. After pouring is completed, the metal composition should be re‑tested to ensure accuracy. If the analysis reveals an inaccurate composition or a metallurgical error, immediate rework is required.
4. Collect the cleaned cast heads (commonly referred to as steel heads) in a centralized manner and mark them for scrapping.
5. Contaminated cobalt-chromium alloys containing small amounts of nickel must be scrapped and are not permitted to enter the production line. For semi-finished metal substructures that have already been cast, if they are detected as contaminated by a metal detector, they must also be isolated, repackaged, and clearly marked.
6. After the components pass inspection, they must be examined for alignment and shrinkage using a magnifying glass and a loupe.
7. Even semi-finished products that have passed metal composition inspection still require high-precision instruments—such as microscopes—to verify the fit of casting edges and the integrity of edge‑finishing lines. Only those that meet the specifications proceed to the next stage; nonconforming items are discarded.
8. The final product also requires a final inspection of the keyboard and mouse detectors.
After undergoing the rigorous procedures outlined above, only qualified dental prostheses are delivered to the clinic for the dentist. By strictly controlling both the manufacturing process and the final product inspection, Despu Instruments employs state-of-the-art XRF alloy analyzers, enabling a transition from subjective visual assessment of metal composition to precise, objective analytical standards. This ensures that the metal materials used for the inner framework of the prosthesis are scientifically sound and appropriately selected for optimal performance in the patient’s mouth, thereby safeguarding the rights and interests of both clinicians and patients.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.