[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Common types of coating thickness gauges and their typical issues!
发布时间: 2022-06-11 10:39
Coating thickness gauge In today’s industrial construction, ensuring engineering quality has made thickness measurement of coatings an indispensable testing tool across various sectors. However, differing measurement principles and precision requirements among industries and products often leave engineers uncertain when selecting the right instrument. Below, we’ll provide a clear overview of the current market’s diverse types of coating‑thickness gauges and address common issues, offering valuable guidance to help you make a more informed purchasing decision.

I. Types of Coating Thickness Gauges
1. Magnetic thickness measurement: Suitable for measuring the thickness of non-magnetic coatings on ferromagnetic substrates.
2. Eddy current thickness measurement: Suitable for measuring the thickness of non-conductive coatings on conductive metals.
3. Ultrasonic thickness measurement: This method is suitable for measuring the thickness of multilayer coatings or for applications where the above two methods are not applicable, such as coating and plating layers on non-metallic materials like glass, ceramics, wood, and plastics.
4. Electrolytic thickness measurement, also known as the coulometric method, involves locally anodically dissolving the metal coating on the area of interest. The coating thickness is determined by measuring the change in electrode potential and the time required for the anodic dissolution to reach the substrate.
5. Radiographic Thickness Measurement: This method is a non-destructive testing technique, with an外形 structure similar to a microwave oven. It uses radiation to analyze coating thickness and is a truly versatile coating thickness gauge.
6. Cross‑hatch thickness measurement: A specialized cutting tool is used to scribe a groove on the coating surface, and the coating thickness is determined by observation and measurement with a calibrated microscope. This method enables layered analysis of various coatings and is widely applied to paint films on plastics, wood, concrete, and other non‑metallic materials.
II. Calibration or Measurement Inaccuracy Caused by Matrix Abnormalities
When using certain instruments for measurement, we often encounter data instability or distorted variations. In such cases, the user should calmly perform a thorough analysis and inspection, for example:
1. Are the substrate or calibration standard sample exhibiting corrosion, rusting, oxidation, wear, contamination, or other such conditions?
2. During instrument calibration, is the sequence of standard samples used in ascending or descending order incorrect?
3. Do the substrate material, thickness, and shape of the actual test object match those of the reference standard used for calibration?
4. During calibration and operation, is the probe in stable contact with the test object?
Because these conditions will directly lead to significant deviations in the measurement results.
III. How to mitigate the impact of external factors on actual measurement data?
1. Users should take proper care to protect both the substrate and the standard specimens to prevent the aforementioned issues. If the substrate becomes corroded or rusted, promptly sand it down to remove the rust and apply a protective coating; it can then continue to be used. However, if the standard specimen is worn, it must be replaced.
2. Instrument calibration typically proceeds from low to high using standard samples; this is known as magnetic field diameter calibration. However, since instruments vary in design, their calibration procedures may differ. Therefore, it is essential to follow the manufacturer’s instructions precisely.
3. Due to variations in magnetic properties arising from differences in material, shape, thickness, and other factors, it is not permissible to perform calibration on substrate A and then use that calibration to measure the coating on substrate B, as this will severely distort the measurement results.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.