[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
How to maintain an ROHS tester?
发布时间: 2022-06-11 10:17
ROHS detector Its primary function is to enter the testing team and detect harmful elements such as lead and mercury. Once these elements are identified, appropriate measures can be taken to address them. Clearly, ROHS testers deliver highly effective and significant results. Therefore, after purchasing a ROHS tester, users should familiarize themselves with proper maintenance practices to extend its service life and ensure optimal performance. So, how should you maintain a ROHS tester? Below are some guidelines compiled by our editor—please take a look!

I. Improving the Test Instrument’s Operating and Internal Environments
The accuracy of an ROHS tester’s detection and measurement is also influenced by external environmental factors, such as temperature. Typically, the temperature should be maintained between 20°C and 25°C; excessively high or low temperatures can disrupt the instrument’s normal operation. In addition to temperature, air humidity must be carefully controlled—avoid excessive moisture, as high humidity can impair the device’s pressure‑regulating and emission‑testing capabilities. Beyond these two factors, nearby magnetic fields, vibrations, and electromagnetic interference from high‑voltage or high‑frequency welding can all compromise the ROHS tester’s measurement precision. Therefore, it is essential to operate the instrument in a relatively quiet environment while maintaining appropriate temperature and humidity levels.
II. Ensuring the Instrument’s Cleanliness and Protection
The ROHS tester should have a clean exterior; prolonged exposure to dust can adversely affect its performance. Therefore, clean the housing and surface, but avoid acidic or alkaline cleaning agents—use neutral detergents instead. Maintain proper cleanliness of the instrument as well, ensuring no foreign objects enter the monitoring window. Keep the monitoring window free of dirt, and do not use hard objects to press against it, as this could cause scratches.
In addition to the two points mentioned above, proper handling during storage and operation is also essential for maintaining your ROHS analyzer. When opening or closing the cover, avoid placing any items unrelated to testing to prevent contamination of the instrument. By following these guidelines, you can effectively extend the service life of your ROHS analyzer, enabling it to detect hazardous elements for a longer period.
The above is an overview of how to maintain an ROHS tester. If you have any questions, please feel free to contact us online for assistance—we’ll promptly provide you with the relevant product information and a quotation.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
