News Center

News Center

How to choose an ROHS 2.0‑compliant instrument?

发布时间: 2022-06-07 09:02

We all know that RoHS 2.0 testing is extremely popular right now—how should you choose? RoHS 2.0 instrument This has become a common question for many. Given that different analytical instruments require distinct sample‑preparation procedures and standard laboratory setups, factories are advised to consider the following recommendations when selecting and purchasing RoHS 2.0‑compliant equipment:

1. Start with the laboratory budget: based on the factory’s budget and financial situation, select an appropriate RoHS 2.0 testing instrument. Avoid blindly assuming that one brand’s RoHS 2.0 analyzer is superior to others. Generally, imported RoHS 2.0 analyzers are significantly more expensive than domestic models, and the more sophisticated the instrument’s configuration, the higher the price—for example, PY‑GCMS typically costs more than GCMS, which in turn costs more than HPLC.

2. Depending on the characteristics of the factory’s own samples, PY‑GCMS can be applied to pure polymer products; however, for samples with highly complex compositions and numerous impurities, chemical extraction is required to prepare the samples, thereby ensuring more reliable data.

3. Regarding factory laboratory conditions and personnel qualifications, conventional physical testing methods such as XRF for component analysis impose relatively modest requirements on the instrument’s operating environment and operator expertise, whereas chemical testing methods demand more stringent laboratory environmental standards and a higher level of technical proficiency from the staff.

4. In response to environmental‑compliance requirements from end users, factories should select ROHS 2.0 testing instruments that are better suited to their needs. Current ROHS 2.0 analyzers are primarily designed to meet the EU’s regulatory requirements; however, as we understand it, many global companies now maintain their own environmental‑management standards. These internal standards often impose even stricter limits than the EU’s unified thresholds, and achieving such low detection limits and high measurement precision typically requires chemical methods such as GC‑MS, HPLC, ICP, or AAS.

5. Consider the scalability of the complete RoHS 2.0 testing system to minimize additional instrumentation investments in the future and meet emerging testing requirements. As environmental protection laws and regulations are constantly evolving, countries are increasingly active in environmental policy and legislation, leading to a growing number of controlled substances and ever‑stricter concentration limits—for example, the list of Substances of Very High Concern (SVHC) under REACH is expanded annually.

The above is an overview of selecting ROHS 2.0‑compliant instruments. If you have any ROHS 2.0 instrument requirements, please feel free to contact us online or by phone—we will promptly provide you with a quotation and detailed product information.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.