[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
The advantages of handheld ROHS analyzers!
发布时间: 2022-06-06 09:14
Handheld ROHS Analyzer Due to its compact size and rapid detection speed, it is widely used for testing children’s toys. It is also employed in the inspection of electronic components and material parts. The widespread adoption of handheld ROHS analyzers stems primarily from their distinct advantages. So, what are these advantages? Let’s take a brief look.

① Fast analysis speed. Measurement accuracy directly affects the measurement duration, but for typical samples, all target elements can be analyzed within 2 to 5 minutes.
②X-ray fluorescence spectroscopy is independent of the chemical bonding state of the sample and is also unaffected by the material’s physical state (solid, powder, liquid, crystalline, amorphous, etc.). However, in high-resolution, precision measurements, phenomena such as wavelength shifts can be observed. This effect is particularly pronounced in the ultra‑soft X-ray region, where wavelength variations are used to determine the chemical potential.
③ Non-destructive analysis. During measurement, the chemical state remains unchanged, and no sample scattering occurs. The same sample can be measured repeatedly, with excellent reproducibility.
④X-ray fluorescence analysis is a physical analytical method; therefore, it can also be used to analyze the chemical properties of elements belonging to the same group.
⑤ Sample preparation is straightforward, and solid, powdered, and liquid samples can all be analyzed.
⑥ High analytical accuracy.
Following the enactment and implementation of the EU Toy Safety Directive, the DEPUS XRF product series has swiftly become a reliable solution for toy manufacturers conducting safety testing. The DEPUS handheld XRF analyzer for hazardous element analysis is easy to use and boasts a wide range of applications.
It can be used for the production of electronic component materials; tripartite assessments of electronic component and raw material suppliers; testing and verification of packaging materials; detection and verification of hazardous substances in various types of batteries; as well as testing of toys, stationery, children’s products, and gifts; non‑obstructed, unrestricted‑space testing of large‑volume parts; precise positioning of small components to eliminate interference; and nondestructive testing of valuable items, among other applications.
The above is an overview of the advantages of handheld RoHS analyzers. If you are in need of a handheld RoHS analyzer, please feel free to contact us online or by phone. We will promptly assist you and provide you with relevant pricing, specifications, and other pertinent information.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.