[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Applications of RoHS detectors in the steel industry!
发布时间: 2022-06-02 09:01
RoHS detector It can perform non‑destructive, accurate, and rapid detection of toxic and hazardous elements in a wide range of materials, including plastics, electronic components, electrical appliances, metals, and solutions. The detection limits for bromine (Br) and mercury (Hg) can reach 1 ppm, and the software interface is simple, clear, and user‑friendly. Samples may be in solid, liquid, or powder form. RoHS analyzers are also applicable in the steel industry; let’s discuss this further.

The application of RoHS detectors in the steel industry extends beyond the analysis of iron and carbon; the primary elements in steel are silicon, manganese, sulfur, and phosphorus. Other alloying elements can also be analyzed using these instruments. Below is a list of key steel components, arranged in alphabetical order, along with their constituent elements:
Carbon: Present in all steels, it is an important hardening element that helps increase the strength of steel. For tool steels, we typically aim for a carbon content of 0.5% or higher, which classifies such steels as high-carbon steels.
Chromium: It enhances wear resistance and hardness, and, more importantly, improves corrosion resistance. Steel is considered stainless when it contains more than 13% chromium. Nevertheless, if not properly maintained, all steels will rust.
Manganese: an essential element that helps form a fine-grained microstructure, enhancing hardness, strength, and wear resistance. During heat treatment and rolling, most steels used for cutting tools are killed steels, with the exception of A‑2, L‑6, and CPM420V steels.
Molybdenum: a carburizing agent that prevents steel from becoming brittle and helps it retain its strength at high temperatures. It is found in many types of steel. Air-hardening steels always contain 1% or more molybdenum, enabling them to harden in air.
Nickel: Maintains strength, corrosion resistance, and toughness.
Silicon: Helps increase strength. Like manganese, silicon is used in steelmaking to maintain the steel’s strength.
Vanadium: Enhances wear resistance and ductility. Vanadium carbides are used to produce patterned steels. Vanadium is present in many types of steel; M‑2, Vascowear, CPMT440V, and 420VA contain significant amounts of vanadium. The difference between BG‑42 and ATS‑34 is that the former contains titanium as a powerful deoxidizer. For finished products—taking stainless steel as an example—users typically focus on the levels of chromium, manganese, nickel, molybdenum, and titanium. These elements vary in content and serve different purposes, and their concentrations can all be measured under atmospheric conditions. Auxiliary equipment such as vacuum pumps is required.
The handheld RoHS tester is a portable testing and analysis instrument specifically designed for the RoHS industry. It employs digital multi-channel technology, offering lower detection limits, superior stability, and performance comparable to benchtop instruments. Its compact size ensures easy portability, making testing operations simpler. The RoHS detector can be regarded as an X-ray fluorescence spectrometer, with an analytical principle identical to that of conventional X-ray fluorescence spectrometers.
The above outlines the applications of RoHS detectors in the steel industry. If you require a RoHS instrument, please contact us via online consultation or by phone, and we will promptly provide you with relevant product information, pricing details, and more.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.