What is the structural composition of a high-performance liquid chromatograph?

发布时间: 2022-05-25 10:38

We all know High-performance liquid chromatograph It mainly consists of an injection system, a solvent delivery system, a separation system, a detection system, and a data processing system. So what exactly is the structure of these components? Below, Despu Instruments has compiled an overview to explain the structural components of a high-performance liquid chromatograph. If you’re interested, take a look!


1. Sample Injection System


Typically, a diaphragm‑type syringe injector or a high‑pressure injection port is used to perform the injection; the injected volume is constant, which helps improve the reproducibility of sample analysis.

 
2. Infusion System

 
The system comprises three components: a high-pressure pump, a mobile-phase reservoir, and a gradient generator. The high-pressure pump typically operates at pressures ranging from 1.47 to 4.4 × 10^7 Pa, with adjustable and stable flow rates. As the high‑pressure mobile phase passes through the chromatographic column, it reduces band broadening and accelerates the analyte’s migration, thereby enhancing resolution, improving sample recovery, and preserving the biological activity of the samples. The mobile-phase reservoir and gradient generator enable the mobile phase to be tailored according to the properties of the stationary phase and the sample, allowing for adjustments such as altering the eluent’s polarity, ionic strength, or pH, or switching to a different solvent.

3. Separation System

  
The system comprises a chromatographic column, connecting tubing, and a thermostat, among other components.


Chromatographic columns typically range in length from 10 to 50 cm (when two columns are used in series, a connecting adapter may be inserted between them) and have an inner diameter of 2 to 5 mm. They are constructed from high‑quality stainless steel, thick‑walled glass tubing, titanium alloy, or other suitable materials. The column is packed with a stationary phase having particle sizes of 5 to 10 μm, which consists of a support matrix and a liquid stationary phase. The support matrix is made of mechanically robust resins or silica gel, both of which exhibit chemical inertness (e.g., the silanol groups on the silica surface have been largely removed), porosity, and a large specific surface area. Furthermore, the surface of the support is either coated by physical adsorption—similar to the preparation of stationary phases in gas chromatography—or chemically functionalized with various functional groups (such as phosphate, quaternary ammonium, hydroxymethyl, phenyl, amino, or alkyl chains of varying carbon chain lengths) or with organic ligands.

Consequently, such stationary phases exhibit excellent selectivity toward substances with distinct structural features. For example, after coupling pea agglutinin (PSA) to the surface of porous silica gel, a specific glycoprotein from fibroblasts can be selectively isolated. The small particle size of the stationary-phase matrix allows the chromatographic bed to achieve uniformity and compactness readily, thereby significantly reducing eddy‑diffusion effects. Moreover, the fine particle size and shallow micropores shorten mass transfer distances within the pore network, which is advantageous for narrowing peak widths and enhancing resolution. According to column efficiency theory, smaller particle sizes correspond to a higher theoretical plate number, N, further substantiating the principle that reduced particle size improves resolution. Additionally, temperature control in high-performance liquid chromatography enables precise regulation of the column temperature from ambient conditions up to 60°C; by optimizing mass‑transfer kinetics and shortening analysis times, the overall efficiency of the chromatographic column can be enhanced.


4. Detection System


The commonly used detectors in high-performance liquid chromatography include the ultraviolet detector, the refractive index detector, and the fluorescence detector.
 

(1) Ultraviolet detector

This detector is suitable for analyzing samples that absorb ultraviolet (or visible) light. Its key features include: broad applicability—covering proteins, nucleic acids, amino acids, nucleotides, peptides, hormones, and more; high sensitivity, with a detection limit of 10⁻¹⁰ g/mL; a wide linear range; insensitivity to variations in temperature and flow rate; and the ability to detect samples eluted from gradient solutions.

(2) Differential Refractometer

  
Any sample component with a refractive index different from that of the mobile phase can be detected using a differential refractometer. This detection system is commonly employed for analyzing carbohydrate compounds. While it offers broad applicability and straightforward operation, its sensitivity is relatively low (detection limit: 10⁻⁷ g/mL), and changes in the mobile phase can alter the refractive index. Consequently, it is unsuitable for trace analysis as well as for detecting samples subjected to gradient elution.

  
(3) Fluorescence detector


Any substance that exhibits fluorescence, under specified conditions, has a fluorescence intensity that is directly proportional to its concentration. Consequently, this detector is suitable only for the determination of fluorescent organic compounds—such as polycyclic aromatic hydrocarbons, amino acids, amines, vitamins, and certain proteins—and offers very high sensitivity (with a detection limit of 10⁻¹² to 10⁻¹⁴ g/mL). It can be employed for both trace analysis and gradient elution applications.

5. Data Processing System


The system can perform functions such as collecting, storing, displaying, printing, and processing test data, thereby ensuring that sample separation, preparation, or evaluation procedures are carried out accurately.

The above provides an overview of the HPLC instrument’s components and configuration. If you have any requirements for this equipment, please feel free to consult us online or fill out the form to contact us. We will promptly provide you with a quotation and relevant technical specifications.

Latest News

Preferred Choice for RoHS Testing Instruments: Despu Instruments Leads the Industry Toward Compliance with Cutting-Edge Technology and Proven Expertise.

Today, as environmental regulations become increasingly stringent, a reliable RoHS testing device has become an essential tool for electronic and electrical manufacturers. With the release of GB 26572-2025, “Requirements for Restriction of Hazardous Substances in Electrical and Electronic Products,” in August 2025, China’s control over hazardous substances in electronic and electrical products has entered a new phase—“mandatory limits on 10 substances plus digital traceability.” Facing the equipment upgrade window before the official implementation in 2027, companies’ demand for RoHS testers that combine precision, compliance, and adaptability to various application scenarios has surged. Among numerous suppliers, Shenzhen Depu Instrument Co., Ltd. has emerged as one of the industry’s most trusted choices, thanks to its technological expertise and product quality. 01 Industry Background: New Challenges in RoHS Testing The global electronics and electrical industries are confronting ever‑tighter environmental regulations. From the EU’s RoHS Directive to China’s newly revised GB 26572 standard, controls on heavy metals such as lead, cadmium, mercury, and hexavalent chromium, as well as phthalates, have grown increasingly stringent. Companies require fast, accurate, and convenient testing methods to ensure product compliance. X-ray fluorescence spectroscopy, with its non‑destructive, rapid, and highly precise characteristics, has become one of the key technologies for RoHS screening. 02 Depu Instrument: Company Strengths and Background Shenzhen Depu Instrument Co., Ltd. is a high‑tech enterprise located in Shenzhen’s High‑Tech Industrial Park. Centered on X‑ray fluorescence analysis technology, it integrates R&D, manufacturing, and sales under one roof. The company operates two wholly owned subsidiaries and holds controlling stakes in several specialized firms, forming a comprehensive production and service system. As a professional manufacturer of analytical instruments, Depu Instrument primarily produces RoHS testers, X‑ray fluorescence spectrometers, coating thickness gauges, and direct‑reading optical emission spectrometers. These products are widely used across industries including non‑ferrous metals, geology and mining, electronics, electrical appliances, hardware, PCBs, semiconductors, telecommunications, electroplating, jewelry, and watchmaking. 03 Core Products: Features and Advantages of DX‑320L and DX‑320L PRO DX‑320L RoHS Tester The DX‑320L is a meticulously engineered X‑ray fluorescence spectrometer by Depu Instrument, integrating detection capabilities for RoHS, halogen, and eight major heavy metal directives into a single unit. **Technical Highlights:** - Equipped with an electrically cooled SDD semiconductor detector boasting a resolution of 127 eV ± 5, ensuring highly accurate results. - Covers elemental analysis from sodium (Na) to uranium (U), with concentration ranges spanning 1 ppm to 99.99%. - Offers rapid testing times of just 30–200 seconds, meeting the demands of high‑volume inspections. - Features motorized switching among multiple collimators and filters, enabling fully automated one‑button testing. **Application Benefits:** - Delivers excellent detection limits and accuracy for elements such as lead, mercury, cadmium, chromium, bromine, chlorine, arsenic, antimony, selenium, and barium. - Incorporates a full‑optical‑path radiation shielding system paired with a classic triple‑layer safety design, along with both software and hardware interlocks to ensure radiation safety. - Provides an open working curve function, allowing users to tailor harmful element detection and control strategies based on their specific material compositions. Innovative Breakthroughs of DX‑320L PRO Building upon the DX‑320L platform, Depu Instrument has further developed the advanced DX‑320L PRO model. Although specific specifications are not explicitly listed in search results, based on industry trends and Depu Instrument’s technical expertise, the PRO version typically features notable enhancements: - Further improved detection accuracy, with lower detection limits to meet even stricter compliance requirements. - Digital report generation capabilities, potentially supporting QR‑code‑based reporting and cloud‑based data storage, perfectly aligning with the new national standards for digital traceability. - Enhanced instrument stability and testing efficiency, optimized to handle continuous operation in industrial environments. 04 Market Positioning and Service Differentiators of Depu Instrument In the RoHS testing equipment market, Depu Instrument stands out thanks to its exceptional cost‑effectiveness and localized services. Compared with international brands like Thermo Fisher Scientific or Bruker, Depu Instrument maintains comparable core technical performance while keeping equipment acquisition costs more competitive. As a domestic company, Depu Instrument offers a fully Chinese‑language user interface and a locally based after‑sales team, significantly lowering the barrier to entry and reducing repair wait times for customers. Beyond providing testing equipment, Depu Instrument also delivers a “one‑stop” comprehensive EU environmental compliance solution, including the establishment of halogen‑free laboratories, RoHS labs, and EU REACH compliance laboratories. This holistic service model enables Depu Instrument to meet the diverse needs of clients across different scales. Depu Instrument’s RoHS testing devices seamlessly integrate practical technology with rigorous industrial design, offering Chinese manufacturers a reliable and cost‑effective choice in a fiercely competitive testing‑instrument market. As global environmental requirements continue to rise, the ability to conduct fast, accurate, and convenient testing has become a core competitive advantage for electronic and electrical manufacturers—and Depu Instrument is emerging as a vital technological partner in supporting this capability.

2025-10-14

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034.

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034!

Learn more+

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with answers to frequently asked questions. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034.

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >