What is the structural composition of a high-performance liquid chromatograph?
发布时间: 2022-05-25 10:38
We all know High-performance liquid chromatograph It mainly consists of an injection system, a solvent delivery system, a separation system, a detection system, and a data processing system. So what exactly is the structure of these components? Below, Despu Instruments has compiled an overview to explain the structural components of a high-performance liquid chromatograph. If you’re interested, take a look!

1. Sample Injection System
Typically, a diaphragm‑type syringe injector or a high‑pressure injection port is used to perform the injection; the injected volume is constant, which helps improve the reproducibility of sample analysis.
2. Infusion System
The system comprises three components: a high-pressure pump, a mobile-phase reservoir, and a gradient generator. The high-pressure pump typically operates at pressures ranging from 1.47 to 4.4 × 10^7 Pa, with adjustable and stable flow rates. As the high‑pressure mobile phase passes through the chromatographic column, it reduces band broadening and accelerates the analyte’s migration, thereby enhancing resolution, improving sample recovery, and preserving the biological activity of the samples. The mobile-phase reservoir and gradient generator enable the mobile phase to be tailored according to the properties of the stationary phase and the sample, allowing for adjustments such as altering the eluent’s polarity, ionic strength, or pH, or switching to a different solvent.
3. Separation System
The system comprises a chromatographic column, connecting tubing, and a thermostat, among other components.
Chromatographic columns typically range in length from 10 to 50 cm (when two columns are used in series, a connecting adapter may be inserted between them) and have an inner diameter of 2 to 5 mm. They are constructed from high‑quality stainless steel, thick‑walled glass tubing, titanium alloy, or other suitable materials. The column is packed with a stationary phase having particle sizes of 5 to 10 μm, which consists of a support matrix and a liquid stationary phase. The support matrix is made of mechanically robust resins or silica gel, both of which exhibit chemical inertness (e.g., the silanol groups on the silica surface have been largely removed), porosity, and a large specific surface area. Furthermore, the surface of the support is either coated by physical adsorption—similar to the preparation of stationary phases in gas chromatography—or chemically functionalized with various functional groups (such as phosphate, quaternary ammonium, hydroxymethyl, phenyl, amino, or alkyl chains of varying carbon chain lengths) or with organic ligands.
Consequently, such stationary phases exhibit excellent selectivity toward substances with distinct structural features. For example, after coupling pea agglutinin (PSA) to the surface of porous silica gel, a specific glycoprotein from fibroblasts can be selectively isolated. The small particle size of the stationary-phase matrix allows the chromatographic bed to achieve uniformity and compactness readily, thereby significantly reducing eddy‑diffusion effects. Moreover, the fine particle size and shallow micropores shorten mass transfer distances within the pore network, which is advantageous for narrowing peak widths and enhancing resolution. According to column efficiency theory, smaller particle sizes correspond to a higher theoretical plate number, N, further substantiating the principle that reduced particle size improves resolution. Additionally, temperature control in high-performance liquid chromatography enables precise regulation of the column temperature from ambient conditions up to 60°C; by optimizing mass‑transfer kinetics and shortening analysis times, the overall efficiency of the chromatographic column can be enhanced.
4. Detection System
The commonly used detectors in high-performance liquid chromatography include the ultraviolet detector, the refractive index detector, and the fluorescence detector.
(1) Ultraviolet detector
This detector is suitable for analyzing samples that absorb ultraviolet (or visible) light. Its key features include: broad applicability—covering proteins, nucleic acids, amino acids, nucleotides, peptides, hormones, and more; high sensitivity, with a detection limit of 10⁻¹⁰ g/mL; a wide linear range; insensitivity to variations in temperature and flow rate; and the ability to detect samples eluted from gradient solutions.
(2) Differential Refractometer
Any sample component with a refractive index different from that of the mobile phase can be detected using a differential refractometer. This detection system is commonly employed for analyzing carbohydrate compounds. While it offers broad applicability and straightforward operation, its sensitivity is relatively low (detection limit: 10⁻⁷ g/mL), and changes in the mobile phase can alter the refractive index. Consequently, it is unsuitable for trace analysis as well as for detecting samples subjected to gradient elution.
(3) Fluorescence detector
Any substance that exhibits fluorescence, under specified conditions, has a fluorescence intensity that is directly proportional to its concentration. Consequently, this detector is suitable only for the determination of fluorescent organic compounds—such as polycyclic aromatic hydrocarbons, amino acids, amines, vitamins, and certain proteins—and offers very high sensitivity (with a detection limit of 10⁻¹² to 10⁻¹⁴ g/mL). It can be employed for both trace analysis and gradient elution applications.
5. Data Processing System
The system can perform functions such as collecting, storing, displaying, printing, and processing test data, thereby ensuring that sample separation, preparation, or evaluation procedures are carried out accurately.
The above provides an overview of the HPLC instrument’s components and configuration. If you have any requirements for this equipment, please feel free to consult us online or fill out the form to contact us. We will promptly provide you with a quotation and relevant technical specifications.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.