News Center

News Center

What are the performance characteristics of a spectrum analyzer?

发布时间: 2021-07-22 11:03

A spectrometer is an instrument used to measure the emission spectrum of a radiating source, thereby determining the source’s intrinsic spectral characteristics.
The analytical principle of a spectrometer is based on the absorption of the characteristic spectral lines of the element to be measured, emitted by a light source, by ground-state atoms of that element in the sample’s vapor. By measuring the degree to which the emission spectrum is attenuated, the concentration of the target element in the sample can be determined. This process conforms to the Beer–Lambert law: A = −lg(I/I₀) = −lgT = KCL, where I is the transmitted light intensity, I₀ is the incident light intensity, T is the transmittance, and L is the optical path length through the atomizer. Since L is a constant, the equation simplifies to A = KC.
Performance Features:
1. The instrument features an independently adjustable exit slit, a domestic first and internationally advanced. This metal‑sealed slit design offers convenient and rapid instrument alignment, facilitates the addition of channels to the exit slit (allowing users to initially focus on the elements currently in use while readily expanding to additional channels as needed), and helps reduce costs.
2. The automated high‑voltage system represents a world‑class standard. It enables computer‑controlled delivery of eight distinct high‑voltage levels per channel, allowing a single channel to be utilized across multiple analytical methods. This enhances channel utilization and optimizes the linear range of spectral lines when analyzing diverse materials, thereby reducing the number of channels required and lowering overall costs.
3. Automatic trace‑generation is at a world‑leading level, filling a domestic gap among comparable instruments. This feature significantly reduces the time required for instrument calibration, making the process simple and convenient; even non‑specialist users can perform trace‑generation operations. The instrument is equipped with an internal temperature‑stabilization system, which greatly minimizes drift in the optical system caused by ambient temperature fluctuations.
4. Chinese-language operating software for the Windows system, designed for convenient domestic use. Operators at different skill levels can access relevant help menus at any time to guide instrument operation; analysis is rapid, with all channel chemical compositions measured within 20 seconds; for various sample types, analysis times are optimized by generating pre‑combustion calibration curves, enabling the instrument to achieve optimal results in the shortest possible time; well‑calibrated working curves are pre‑installed, eliminating the need to purchase large quantities of standard samples, thereby reducing costs, and allowing immediate use upon installation.
5. A domestically unprecedented multifunctional light source. The adoption of this multifunctional light source broadens the elemental analysis range, enabling the determination of both ultra‑high‑concentration and trace elements. Each subsystem is independently powered, and the modular design ensures quick and convenient maintenance. This modular architecture allows even non‑specialist personnel to perform rapid repairs, fully preparing the instrument for remote diagnostics over the internet.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >