News Center

News Center

Shaanxi ROHS Testing Instrument Buying Guide | Professional Recommendations from Despu Instruments!

发布时间: 2025-07-18 13:36

I. Procurement Channels for ROHS Instruments in Shaanxi Province
1. Official brand direct purchase
- It is recommended to contact first. ROHS testing instrument The brand’s Shaanxi branch or headquarters—such as Despu—should secure official distribution channels to avoid markups from intermediaries.
- Advantages: Original manufacturer’s technical support, after-sales warranty, and equipment calibration services.

2. Local scientific instrument supplier
- Cities such as Xi’an and Baoji have specialized distributors of laboratory equipment, offering ROHS testing instruments (e.g., XRF spectrometers, chemical analyzers, etc.).
- It is recommended to check the official website of the Shaanxi Instrument and Meter Industry Association for certified suppliers.

3. Online Procurement Platform
On B2B platforms such as Ai Cai Gou and Chemical Instrument Network, search for “Despu Instruments” and filter for suppliers with ISO certification.
Note: Verify that the equipment complies with the Chinese national standard (GB/T 26125-2011) and the EU RoHS 2.0 directive.

 RoHS detector II. Why recommend Despu Instruments?
1. Brand Strength
DePu is a leading domestic brand of ROHS testing equipment, specializing in the research and development of X-ray fluorescence spectrometers (XRF). Its products are certified to CE and CNAS standards, with accuracy reaching the ppm level.

2. Concierge-level service
DePu can provide on-site installation, operator training, and routine maintenance in Xi’an, with rapid response times.

3. Recommended High-Value Models
DX320L: XRF, suitable for rapid screening of plastic and metal materials, detects six major hazardous substances including lead, cadmium, and mercury, and performs coating analysis.
PY8060: Laboratory-grade equipment that supports ROHS 2.0 compliance testing, with data exportable directly into compliant reports.

4. Success Stories
We serve numerous electronic manufacturing enterprises in Shaanxi Province, including supply-chain vendors for BYD in Xi’an, and our equipment’s stability has earned industry-wide recognition.

III. Procurement Recommendations
1. Budget Planning: XRF equipment costs approximately RMB 70,000–150,000, while laboratory equipment ranges from RMB 200,000 to 500,000; selection should be based on testing requirements.
2. Verification of Qualifications: Suppliers are required to provide equipment calibration certificates and ROHS‑compliant standard substance test reports.
3. After-sales terms: Confirm the warranty period (recommended to be at least 2 years) and the cost of replacing consumables, such as the X-ray tube.

Tip: Before purchasing, we recommend scheduling an on-site demonstration with a Despu engineer to compare measurement accuracy and ease of use.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >